Products | RCD/Fi-Testers | TELARIS RCD-TEST

TELARIS RCD-TEST


TELARIS_RCD-TEST Technical data
Display 3½ digit, LCD, 1999 Count
Nominal Test Current 10 / 30 / 100 / 300 / 500mA/ 1 A (time delayed: 100mA/ 300mA/ 500 mA / 1 A)
Contact Voltage 0.6...70 V / 0.1 V
Tolerance (-0%...+10%) + 6 Digits
RCD Trip Time 2...1999 ms / 1 ms
Tolerance ±(2%+2 Digits)
Test Curren Type AC, DC, DC pulse
Earth Resistance 0.01...1999 Ω / 1 Ω
Tolerance ±(10%+10 Digits)
Mains Voltage 230 V +10% / -15%
Memory approx. 100 measurements
Interface IR/RS-232 interface-adapter
Safety Complying with IEC61010/EN61010/DIN VDE 0411, IEC61557/EN61557/DIN VDE 0413
Overvoltage category CAT III / 300 V
Pollution Degree 2
Protection Degree IP 50
Power Supply 6 x 1.5 V, IEC LR6
Dimensions approx. 235 x 105 x 70 mm
Weight approxx. 650 g
Quick-Links
Order Documents
NEW AT-Series Underground Cable Locators
NEW! Mini Infrared Thermometer IR-500